CONTACTORS
3 Pole Power Contactors- Type MNX
- Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
- Range from 9A- 650A AC-3
- Click fit type construction up to 40A
- Coil on top design in 95A and above
- Spares available for entire range
3 Pole Power Contactors- Type ML
- Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
- Range from 25-300A AC-3
- Robust and suitable for hostile applications
Capacity Duty Contactors- Type MO C
- Conforms to 60947-4-1 & IEC 60947-4-1
- MO C Range available from 3- 100kVAr, AC-6b
- Delatching type early make contacts
- Separate termination for damping resistors
- Encapsulated damping resistor assembly
- Common coil for 50-60Hz application
- Low pick-up VA consumption
- Standard accessories throughout the range in lined with MO contactor
- Suitable for Lug as well as Lugless termination
RELAYS
Thermal Overload Relays- Type MN
- Available in 3 frame sizes from 0.2-570 A
- Ambient temperature compensated up to 55.C
- Built-in Single Phasing protection
- Manual and auto reset mode
- Conforms IS/IEC 60947-4-1 & IEC 60947-4-1
Thermal Overload Relays- Type ML
- Direct mounting on MX contactor
- Built-in single phasing protection
- Front access to START and STOP/RESET buttons
Electronic Motor Protection Relay With in-built Earth Fault Protection
- Overload
- Earth Fault
- Locked Rotor
- Single Phasing, Current Unbalance, Phase Sequence Reversal
- Under Current
- Inbuilt CT’s (1A to 88A)
- Trip indication
- Test facility
- Selectable trip class- 10A, 10, 20 and 30 as per IEC 60947-4-1
MCB’s
Motor Protection Circuit Breakers
- MOG-H1M: upto 32A
- MOG-H2M: 32A-63A
- Short circuit protection
- Icu=100kA upto 13A & Icu=50kA from 16A-63A
Motor Protection Circuit Breakers
- MOG-H1: upto 32A
- MOG-H2: 32A-63A
- Short circuit+ Overload protection
- Icu= 100kA upto 13A & Icu=50kA from 16A-63A
SWITCHES
On Load Changeover Switch- Disconnectors
Changeover Switch- Disconnector
Features offered by Manual Changeover
- Range 63A to 2000A, 415V, AC 23A, 4P
- Enclosure version does not require separate cable gland box
- Terminal Shrouds, Source Separator and Phase Barriers included
- Staggered Terminals make cable termination easy
- Suitable for horizontal as well as vertical mounting
Features offered by Motorized Changeover
- Range 125A to 2000A, 415V, AC 23A, 4P( Control Voltage 240 Vac)
- No change in HxWxD dimension of motorized and manual changeover switch
- Padlocking in OFF position
- Option for selection between manual and auto mode
Switch –Disconnector-Fuse Units
Type TPN S-D-F suitable for DIN fuse-link (TPN & FP) in open execution
- Range 32A to 800A,415V , AC 23A
- Terminal shrouds on both sides and phase barriers include
- Telescopic shaft for depth adjustment
- TPN SDF has isolable netural 4P SDF has switched Netural pole and is 100% rated
- Door interlock & padlock facility
FN-TPN S-D-F in SS enclosure
- Range 32Ato 800A,415V, AC 23A
- Spacious sheet steel enclosure
- Separate cable gland box not required
- Terminal shrouds on both sides and phase barriers include
- Conforms to IEC 60947-3, IS/IEC 60947-3
- Door interlock and padlock facility
FUSES
HRC Fuses
- Conforms to IEC60269-2, IS 13703 part 2
- Range: 2Ato 800A, 415V, AC 50Hz
- Type cylindrical(2Ato 63A),DIN (63A to 800A) & Bolted(2A to 630A)
- High breaking capacity 100kAfor type HN and 80kA for type HF/HG/HQ
MCCBs
MCCB Range with thermal- Magnetic Release:
- Conforms to IS/IEC 60947-2
- 20A to 630A, 3P&4P
- 25kA, 36kA, 50kA & 70kA braking capacities
- Ics=100%of Icu*
- Adjustable overload settings: 0.8 -1.0 * In
- Adjustable short-circuit settings 6-10 * In
- Manual, Rotary and Motorised versions available
- Wide range of accessories
ACB’s
Air circuit breakers
- Current rating from 400A to 6300A in 3 frame sizes for application voltages upto 690V AC
- Special ACB range available for Voltage Applications upto 800V AC and 1000V AC#
- Available in 3Pole/Pole, manually & electronically operated, Fixed/ Draw-out version
- Common height & depth across range
- High mechanical and electrical operating life
- In built electrical & mechanical anti-pumping
- Modular and snap-fit accessories
- Ease of on-site conversion from fixed to draw-out version
- Pollution degree 4 suitability
- Best in class overlap with bus bars
- Break time 25msec
- RoHS compliant
Air circuit breakers
- Current rating from 400A to 3200A
- Available in 3 pole/4 pole, manually and electrically operated, fixed and draw outversions
- High short time withstand capacity, Icu=Ics=Icw for 1 sec for total selectivity
- High mechanical and electrical operating life
- 100% rated neutral pole
- Common height and depth across range
- Protection through thermal- magnetic (DN1)& microprocessor releases
- Inbuilt thermal memory
- Protection releases conform to EMI/EMC standards
- Breaker status and control through MODBUS protocol (UN-CO module)
CAPACITORS
Heavy duty capacitors & Super heavy duty capacitors
- Industries only ultra heavy duty capacitors in cylindrical configuration
- Proven performance even under harsh power quality conditions
- Highest inrush current withstand ability
- Highest life with optimized space
- Maximum temperature upto 70 degrees C
- Space economy in APFC panels with cylindrical design
METERING DEVICES
Single phase kWh meter with LCD display
Energy meters 4000 series
- Accuracy class1.0, 0.5
- Input voltage measurement range 50-520 VAC (P-P)
- Aux supply 80-300 VAC/DC
- CT secondary site selectable 1A/5A
- Flush mounting 96*96mm
- CT/PT site programmable
- Auto scaling of kilo, mega and giga
MCB
Range highlights
- True contact indication for individual pole
- Lable holder facility for all configurations
- Conforms to IS/ICE 60898-10kA
- Available in B,C&D curves
- Low watt loss – almost 50% of the values prescribed by IS/IEC 60898
- Trip free mechanism
- Design based on advanced current limiting hammer trip mechanism
- No line load bias
- Suitable for accessory fitment
SPN DB
- Conforms to IS 8623-1 &3 IEC 61439-1&3
- Ik 08- for single door DBs, IK09 for double door DBs
- Available in CRCA sheet steel, RAL9003, Power coated
- With provision for DP MCB/ Isolator/ RCCB/RCBO as incomer and SP MCBs as outgoings
TPN DB
- Conforms to IS 8623-1 &3 IEC 61439-1&3
- Ik 08- for single door DBs, IK09 for double door DBs
- Available in CRCA sheet steel, RAL9003, Power coated
- With provision for FP MCB/ Isolator/ RCCB/RCBO as incomer and SP MCBs as outgoings