CONTACTORS

images
3 Pole Power Contactors- Type MNX
  • Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
  • Range from 9A- 650A AC-3
  • Click fit type construction up to 40A
  • Coil on top design in 95A and above
  • Spares available for entire range
3 Pole Power Contactors- Type ML
  • Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
  • Range from 25-300A AC-3
  • Robust and suitable for hostile applications
images
images
Capacity Duty Contactors- Type MO C
  • Conforms to 60947-4-1 & IEC 60947-4-1
  • MO C Range available from 3- 100kVAr, AC-6b
  • Delatching type early make contacts
  • Separate termination for damping resistors
  • Encapsulated damping resistor assembly
  • Common coil for 50-60Hz application
  • Low pick-up VA consumption
  • Standard accessories throughout the range in lined with MO contactor
  • Suitable for Lug as well as Lugless termination

RELAYS

Thermal Overload Relays- Type MN
  • Available in 3 frame sizes from 0.2-570 A
  • Ambient temperature compensated up to 55.C
  • Built-in Single Phasing protection
  • Manual and auto reset mode
  • Conforms IS/IEC 60947-4-1 & IEC 60947-4-1
images
images
Thermal Overload Relays- Type ML
  • Direct mounting on MX contactor
  • Built-in single phasing protection
  • Front access to START and STOP/RESET buttons
Electronic Motor Protection Relay With in-built Earth Fault Protection
  • Overload
  • Earth Fault
  • Locked Rotor
  • Single Phasing, Current Unbalance, Phase Sequence Reversal
  • Under Current
  • Inbuilt CT’s (1A to 88A)
  • Trip indication
  • Test facility
  • Selectable trip class- 10A, 10, 20 and 30 as per IEC 60947-4-1
images

MCB’s

images
Motor Protection Circuit Breakers
  • MOG-H1M: upto 32A
  • MOG-H2M: 32A-63A
  • Short circuit protection
  • Icu=100kA upto 13A & Icu=50kA from 16A-63A
Motor Protection Circuit Breakers
  • MOG-H1: upto 32A
  • MOG-H2: 32A-63A
  • Short circuit+ Overload protection
  • Icu= 100kA upto 13A & Icu=50kA from 16A-63A
images

SWITCHES

images

On Load Changeover Switch- Disconnectors
Changeover Switch- Disconnector
Features offered by Manual Changeover

  • Range 63A to 2000A, 415V, AC 23A, 4P
  • Enclosure version does not require separate cable gland box
  • Terminal Shrouds, Source Separator and Phase Barriers included
  • Staggered Terminals make cable termination easy
  • Suitable for horizontal as well as vertical mounting
Features offered by Motorized Changeover
  • Range 125A to 2000A, 415V, AC 23A, 4P( Control Voltage 240 Vac)
  • No change in HxWxD dimension of motorized and manual changeover switch
  • Padlocking in OFF position
  • Option for selection between manual and auto mode
images
images
Switch –Disconnector-Fuse Units

Type TPN S-D-F suitable for DIN fuse-link (TPN & FP) in open execution

  • Range 32A to 800A,415V , AC 23A
  • Terminal shrouds on both sides and phase barriers include
  • Telescopic shaft for depth adjustment
  • TPN SDF has isolable netural 4P SDF has switched Netural pole and is 100% rated
  • Door interlock & padlock facility
FN-TPN S-D-F in SS enclosure
  • Range 32Ato 800A,415V, AC 23A
  • Spacious sheet steel enclosure
  • Separate cable gland box not required
  • Terminal shrouds on both sides and phase barriers include
  • Conforms to IEC 60947-3, IS/IEC 60947-3
  • Door interlock and padlock facility
images

FUSES

images
HRC Fuses
  • Conforms to IEC60269-2, IS 13703 part 2
  • Range: 2Ato 800A, 415V, AC 50Hz
  • Type cylindrical(2Ato 63A),DIN (63A to 800A) & Bolted(2A to 630A)
  • High breaking capacity 100kAfor type HN and 80kA for type HF/HG/HQ

MCCBs

MCCB Range with thermal- Magnetic Release:
  • Conforms to IS/IEC 60947-2
  • 20A to 630A, 3P&4P
  • 25kA, 36kA, 50kA & 70kA braking capacities
  • Ics=100%of Icu*
  • Adjustable overload settings: 0.8 -1.0 * In
  • Adjustable short-circuit settings 6-10 * In
  • Manual, Rotary and Motorised versions available
  • Wide range of accessories
images

ACB’s

images
Air circuit breakers
  • Current rating from 400A to 6300A in 3 frame sizes for application voltages upto 690V AC
  • Special ACB range available for Voltage Applications upto 800V AC and 1000V AC#
  • Available in 3Pole/Pole, manually & electronically operated, Fixed/ Draw-out version
  • Common height & depth across range
  • High mechanical and electrical operating life
  • In built electrical & mechanical anti-pumping
  • Modular and snap-fit accessories
  • Ease of on-site conversion from fixed to draw-out version
  • Pollution degree 4 suitability
  • Best in class overlap with bus bars
  • Break time 25msec
  • RoHS compliant
Air circuit breakers
  • Current rating from 400A to 3200A
  • Available in 3 pole/4 pole, manually and electrically operated, fixed and draw outversions
  • High short time withstand capacity, Icu=Ics=Icw for 1 sec for total selectivity
  • High mechanical and electrical operating life
  • 100% rated neutral pole
  • Common height and depth across range
  • Protection through thermal- magnetic (DN1)& microprocessor releases
  • Inbuilt thermal memory
  • Protection releases conform to EMI/EMC standards
  • Breaker status and control through MODBUS protocol (UN-CO module)
images

CAPACITORS

images
Heavy duty capacitors & Super heavy duty capacitors
  • Industries only ultra heavy duty capacitors in cylindrical configuration
  • Proven performance even under harsh power quality conditions
  • Highest inrush current withstand ability
  • Highest life with optimized space
  • Maximum temperature upto 70 degrees C
  • Space economy in APFC panels with cylindrical design

METERING DEVICES

Single phase kWh meter with LCD display

Energy meters 4000 series

  • Accuracy class1.0, 0.5
  • Input voltage measurement range 50-520 VAC (P-P)
  • Aux supply 80-300 VAC/DC
  • CT secondary site selectable 1A/5A
  • Flush mounting 96*96mm
  • CT/PT site programmable
  • Auto scaling of kilo, mega and giga
images

MCB

images
Range highlights
  • True contact indication for individual pole
  • Lable holder facility for all configurations
  • Conforms to IS/ICE 60898-10kA
  • Available in B,C&D curves
  • Low watt loss – almost 50% of the values prescribed by IS/IEC 60898
  • Trip free mechanism
  • Design based on advanced current limiting hammer trip mechanism
  • No line load bias
  • Suitable for accessory fitment
SPN DB
  • Conforms to IS 8623-1 &3 IEC 61439-1&3
  • Ik 08- for single door DBs, IK09 for double door DBs
  • Available in CRCA sheet steel, RAL9003, Power coated
  • With provision for DP MCB/ Isolator/ RCCB/RCBO as incomer and SP MCBs as outgoings
images
images
TPN DB
  • Conforms to IS 8623-1 &3 IEC 61439-1&3
  • Ik 08- for single door DBs, IK09 for double door DBs
  • Available in CRCA sheet steel, RAL9003, Power coated
  • With provision for FP MCB/ Isolator/ RCCB/RCBO as incomer and SP MCBs as outgoings

RCCB's

Timers, Indicators & Push buttons